– 1 –NSTRUCTIONSIINFRARED BOOSTER . . . Gas Water HeatersMODELIB57 ML-110898IB140 ML-110899IB235 ML-110861IB290 ML-110862INFRAREDBOOSTER701 S. RIDG
– 10 –WATER REQUIREMENTSProper water quality can improve ware washing performance by reducing spotting, lowering chemicalsupply costs, enhancing effec
– 11 –SHOWN WITH OPTIONAL WATER HAMMER ARRESTOR KITFig. 6The heater is equipped with a pump which circulates water inside the booster heater and maint
– 12 –ELECTRICAL CONNECTIONSWARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH APPLICABLEPORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR O
– 13 –
– 14 –START UP PROCEDURES — FOR YOUR SAFETY READ BEFORE OPERATINGFilling the Booster PipingFill the booster heater with water, purging all air. Mak
– 15 –Hot Surface Ignition Using the Robertshaw Gas Valve1. STOP! Read the safety information.2. Turn off all electrical power to the appliance.3. Re
– 16 –OPERATIONThe booster heater is designed to deliver 180°F water, up to the gallons per minute and gallons perhour ratings specified in the table
– 17 –MAINTENANCELUBRICATIONThe water pump motor and the combustion air blower motor are permanently lubricated and requireno other maintenance.VENT S
– 18 –LIST OF REPLACEMENT PARTSWhen ordering parts, be sure to provide the Model Number, ML Number, and Serial Number from thedata plate located on th
– 19 –Components (Pump Side) continuedPART No. NAME OF PART AMTFP 047-12 FITTING-TUBE 5/8 TBG FERRULE (140,000 & 235,000 BTU/Hr) . . . . . . . . .
– 2 –IMPORTANT FOR YOUR SAFETYWARNING: IF THE INFORMATION IN THESEINSTRUCTIONS IS NOT FOLLOWED EXACTLY,A FIRE OR EXPLOSION MAY RESULT CAUSINGPROPERTY
– 20 –Components (Pump Side) continuedPART No. NAME OF PART AMT00 294500 040-1 TRANSFORMER, 30VA, 50/60HZ . . . . . . . . . . . . . . . . . . . . . .
– 3 –TABLE OF CONTENTSIMPORTANT FOR YOUR SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2GENERAL .
– 4 –Installation, Operation, and Care ofINFRARED BOOSTER GAS WATER HEATERSSAVE THESE INSTRUCTIONSGENERALThe Infrared Booster Gas Water Heaters (avail
– 5 –INSTALLATIONUNPACKINGImmediately after unpacking, check for possible shipping damage. If the Booster Heater is found tobe damaged after unpackin
– 6 –VENTING REQUIREMENTSWARNING: PROVIDE A SCREEN OR BARRIER TO PREVENT PERSONAL INJURY IN AREASWHERE INADVERTENT PERSONNEL CONTACT WITH THE HOT VEN
– 7 –Fig. 2Fig. 3Dish Table or ConveyorDishwasherCombustible SidewallTermination Termination Tee6"Termination TeeNon-Combustible SidewallTermina
– 8 –Fig. 4All horizontal runs of the vent pipe shall have a minimum rise of 1/4" per foot of length and should besupported every 5 feet or less
– 9 –GAS CONNECTIONFor model IB57, the gas inlet pipe size is 1/2" NPT at the gas valve. For models IB140, IB235, and IB290,the gas inlet pipe
Kommentare zu diesen Handbüchern